Capacitive sensor Circuit test report

Intention:

This test try to acquire the parameters of test circuits(oscillating circuit), as power consumption, long-term stability (the relation between Temperature, Supply Voltage), and Sensitivity from 0% to 100% RH (the capacitance alter range of humidity sensor is 40pF, 200pF~240 pF).

Test circuits:

figure1, figure2 and figure5 has a duplicate copy, named figure1′, figure2′, figure5′. The duplicate copy is used for consistency check.

image

image

image

image
Note: Tolerance of resistors tolerance is 5%, temp. coeff. is ±200ppm; Tolerance of capacitors is 5%.


The process of test:

  1. Power Supply Current range (Vcc 2.70V~3.30V) Unit: mA
    image

  2. Capacitive sensor = 246 pF, the follow table is the relation between Power Supply Voltage and output frequency. Ambient temperature is 23.3℃
    image

image

image

image

3.Power Supply Voltage = 3V, the value of capacitive sensor is modified(180pF~246 pF). ambient temperature is 23.7℃
image

image

image

image

4.Temperature stability test.
a) Power Supply Voltage = 3V, the value of capacitive sensor is 246pF.
image
Note: figue1,figue1′R=470Ω. figue2′ the same as figue2.

b) Power Supply Voltage = 2.84V, the value of capacitive sensor is 246pF.
image
Δf/Δfrange 5.72% 12.49% 1.78% 2.20% 3.98% 3.18% 2.92%
Note: figue1,figue1′R=0Ω. figue2′ the same as appendix figueA.


Analyze:

With the above test:
About figure1,
a) when R=0Ω,the temperature stability is better than R=470Ω, because when R=470Ω, it combine the stray capacitance and Input Capacitance of HC14 become a charge/discharge part, the capacitance is master factor that affect output frequency.

b) VT+ and VT- of 74HC14 as follow figure, the alter range are very too large.
image

the output frequency dependent the hysteresis. Follow are test data in different frequency:
image
We can find the different output frequency cannot improve the precision.

About figure2,
a) the offset voltage of LM393 is master factor that affect the precision of output frequency. So we should increase the hysteresis. This increase reduces affect of the offset voltage. The test data as follow table shows:
image

About figure3,
Too high frequency, not easy to measure, give up。

About figure5,
the lower frequency can improve the temperature stability. The test data as table shows.
image

Appendix:

image
Note: Tolerance of resistors tolerance is 5%, temp. coeff. is ±200ppm; Tolerance of capacitors is 5%.

Long-term stability test. Power Supply Voltage = 3.00V
image


这就是当初做的测试,综合所有因素来看,figure5是最优选择。

在我工作以后,类似的测试也做过不少,测试的方法大概和这个都一样,所以说,大学里面学到的知识和做事方法,对我的工作帮助还是很大的。


希望喜欢我文字的人,去看看这个吧,说说对我的看法,请我吃星星5 cred stars,谢谢啦~
我的 @ReviewMe 凭证留言板!

Posted using Partiko iOS


This page is synchronized from the post: Capacitive sensor Circuit test report | 电容传感器线路测试报告

Your browser is out-of-date!

Update your browser to view this website correctly. Update my browser now

×